Sentrum 6

HAYES

Located within an established trading estate in west London, Sentrum Hayes provides 47,000 sq ft of net technical space together with 30,000 sq ft of offices and disaster recovery suites. Colocation is also available at this site via our sister company Sentrum Colo.

The facility is designed to a Tier III+ level of resilience and is List X with additional bomb-blast walling which ensures the highest levels of security are available.

 

Sentrum Hayes at a Glance:

  • 47,000 sq ft data centre / technical space
  • 30,000 sq ft dedicated offices and disaster recovery suites
  • High density solutions up to 2000 watts/sq m
  • List X rating

 

Building

  • High density solutions from 1000 to 2000 watts per sq m and higher if required.
  • 24 x 7 x 365 building operation
  • 750mm raised floor with 4 metres to underside of soffit
  • Secure managed delivery bay with 3 tonne goods lift
  • Floor loading 10KN per sq m

Power

  • Mains power supplied via 3 x 11kV incomers 12MVA
  • N+ N power solutions
  • Minimum N+N UPS with battery back-up
  • Back-up generators
  • Refuelling contracts to ensure timely replacement

Cooling

  • Minimum N+1 cooling infrastructure
  • Primary cooling infrastructure, centrally managed and linked to BMS
  • Room air conditioning units
  • Regulated humidity

Fire Detection & Suppression

  • Three stage fire detection systems in all plant areas
  • VESDA (Very Early Smoke Detection Apparatus)
  • Fire detection in all rooms, below raised floors and in ceiling voids
  • Water sprinklers on the ground floor
  • Double interlocked pre-action gas suppression to technical areas
  • Fire detection and suppression systems interconnected to central BMS

Security

  • 24 x 7 on-site security
  • Proximity cards to authorise access levels including mantrap access
  • Door access controls at site and building entrances
  • External and internal CCTV
  • Intruder detection alarms
  • 3 metre secure perimeter fence with rotary spikes
  • Vehicle lock to site entrance
  • X-ray scanners

Building Management System

  • Power monitoring and building monitored systems to provide alarms
  • Power surge management
  • Dedicated 24 x 7 facilities management team
  • 24 x 7 on-site M&E engineers undertaking Planned Preventative Maintenance (PPM) programmes

Connectivity

  • Access to multiple telecommunication providers
  • Diverse cable routing into facility
  • Strict cable management policy

Disaster Recovery

  • 500 disaster recovery desks which can be leased on either a dedicated or syndicated basis
  • Low syndicated ratios
  • Trading and non-trading positions
  • PC / desktop infrastructure
  • Printers, photocopiers and fax machines
  • Replay and voice recorders per suite
  • Meeting rooms
  • Breakout areas
  • Vending machines
  • Reception services
  • Floor loading 4+1KN per sq m